Comparison between Retention of Maxillary Acrylic and Nylon Denture Base Materials

Authors

DOI:

https://doi.org/10.25156/ptj.v10n1y2020.pp38-42

Keywords:

Polymethylemethacrylate, strain gauge, Valplast, Denture retention, Nylon

Abstract

Loss of teeth is a matter of great concern to majority of the people and their replacement by artificial substitutes, such as dentures, is vital to the continuance of normal life. One of the factors influence patient responses regarding their complete dentures is the quality of retention. Complete denture base is composed of heat polymerized polymethylemethacrylate (PMMA). However, this material presents limitations, particularly in terms of flexural and impact strength and patients representing allergic reaction to PMMA. Nylon denture base material could be useful alternative to PMMA, especially in the patient shows allergy to PMMA. This study was conducted to estimate the difference between retention of conventional acrylic and Valplast maxillary denture base. Ten edentulous patients (five males and five females) with an age range of 45–60 years. For each patient two maxillary dentures were constructed, one from acrylic resin and other from Valplast denture base materials. Specially designed strain gauge–measuring device was used to measure the force required to dislodge the two dentures from basal seats. Six measurements of retention of newly inserted denture base were recorded for each patient (three for maxillary acrylic denture base and three for maxillary nylon denture base). Using paired t-test, a significant improvement in retention obtained by nylon denture base materials in comparison with conventional maxillary acrylic denture base, for both male and female. The retention force that obtained for each patient does not represent the quality of retention for that patient, because we measured the retention at static state and the measurements for each patient were done at same visit of insertion.

Downloads

Download data is not yet available.

References

Al-Loaibi, M. A. 2004. Effect of Palatal Reduction on Retention of Maxillary Complete Denture, M.Sc. Thesis. College of Dentistry, University of Baghdad, Baghdad.

Al-Shedidi, A. M. H. 2002. The Effect Air Abrasive Particles on the Retention of the Maxillary Complete Denture, M.Sc. Thesis. College of Dentistry, University of Baghdad, Baghdad.

Anusavice, K. J. 2003. Phillips’ Science of Dental Materials. 10th ed. Saunders, Philadelphia, PA. p89-92.

Baemmert, R. J., B. R. Lang, M. T. Jr. Barco and E. J. Billy. 1990. Effects of denture teeth on the dimensional accuracy of acrylic resin denture bases. Int. J. Prosthodont. 3: 528-537.

Barclay, S. C., H. A. Forsyt, D. H. Felix and I. B. Watson. 1999. Case report: Hypersensitivity to denture materials. Br. Dent. J. 187: 350-352.

Darvell, B. W. and R. K. Clark. 2000a. The physical mechanism of complete denture retention. Br. Dent. J. 139(5): 248-252.

Gomes, M., J. R. Broilo, L. F. Walber, P. C. A. Maccari and R. S. A. Shinkai. 2004. Adaptation of complete denture bases submitted to chemical polishing. J. Appl. Oral Sci. 12(4): 322-325.

Hasan, R. U., A. Gurbuz, N. Ozden and F. Kezim. 1998. Evaluation of reproducibility of the peripheral tissues in the edentulous patients. Turk. J. Med. Sci. 28: 291-294.

Jackson, A. D., B. R. Lang and R. F. Wang. 1993. The influence of teeth on denture base processing accuracy. Int. J. Prosthodont. 6: 333-340.

Jagger, D. C., A. Harrison and K. D. Jandt. 1999. The reinforcement of dentures. J Oral Rehabil. 26: 185-194.

Jarkas, M. I. 2007. Comparison of Hypoallergenic Denture Base Material Plastics, Dental Medicine. Halle-Wittenberg, Germany.

Kapur, K. K. 1967. A clinical evaluation of denture adhesives. J. Prosthet. Dent. 18: 550-558.

Matthews, E. and D. C. Smith. 1955. Nylon as a denture base material. Br. Dent. J. 98: 231-237.

Monsenego, P. and J. Proust. 1989. Complete denture retention. Part I: Physical analysis of the mechanism. Hysteresis of the solidliquid contact angle. J. Prosthet. Dent. 62: 189-196.

Navtar, N., H. Edt. and M. Sabet. 2005. A study of effect of border molding on effective efficiency of maxillary complete denture. Cairo Dent. J. 21(2): 135-140.

Noort, R. V. 2002. Introduction to Dental Materials. 2nd ed. Elsevier Science Limited, Amsterdam.

Schreiber, C. K. 1971. Polymethylmethacrylate reinforced with carbon fibres. Br. Dent. J. 130: 29-30.

Shay, K. 1997. Boucher’s Prosthodontic Treatment for Edentulous Patients. 11th ed. Mosby-Yearbook, Inc., St Louis.

Takamata, T. and J. C. Setcos. 1989. Resin denture bases: Review of accuracy and methods of polymerization. Int. J. Prosthodont. 2: 555-562.

Teraoka, F., M. Nakagawa and J. Takahashi. 2004. Retention force of complete palate coverage and palate-less dentures in vitro. Dent. Mater. J. 23(1): 19-23.

The Academy of Prosthodontic. 2005. The glossary of prosthodontic term. J. Prosthet. Dent. 94: 31.

Published

2020-06-30

How to Cite

Abdulkareem, H. S., & Salem, S. A. (2020). Comparison between Retention of Maxillary Acrylic and Nylon Denture Base Materials. Polytechnic Journal, 10(1), 38-42. https://doi.org/10.25156/ptj.v10n1y2020.pp38-42

Issue

Section

Research Articles

Most read articles by the same author(s)