Root Dentine Strain Generation during Root Canal Instrumentation with Rotation and Reciprocation Motions

Authors

DOI:

https://doi.org/10.25156/ptj.v10n2y2020.pp66-70

Keywords:

Endodontics, Instrumentation, Reciprocation motion, Root canal, Root dentine strain, Rotation motion

Abstract

The aim of the study is to measure and compare strain generated on root dentine surface by two different instrumentation motions. Thirty extracted single canal premolars were used in this study which randomly was divided into two groups, one group was prepared with ProTaper NEXT X2 file in rotation motion, and the second group was prepared by WaveOne GOLD primary file in reciprocation motion, the canals were irrigated during canal preparation by 2 ml of sodium hypochlorite and 17% EDTA gel was used. Strain measurement was performed by strain gauges and a digital strain output reader, data were recorded every 5 s for 50 s. The results of this study have shown that WaveOne GOLD had higher mean 0.7308±0.41106 than ProTaper next 0.5385±0.39904 which means WaveOne GOLD generates greater strain than ProTaper NEXT. However, according to Student’s t-test between two groups there is no statistical difference between them. Based on the results of this study, there was no difference between the two motions; both motions generated strain on root dentine surface.

Downloads

Download data is not yet available.

References

Amade, E. S., V. R. Novais, M. G. Roscoe, F. M. F. Azevedo, A. A. Bicalho and C. J. Soares. 2013. Root dentin strain and temperature rise during endodontic treatment and postrehabilitation. Braz. Dent. J. 24: 591-598.

Bürklein, S., P. Tsotsis and E. Schäfer. 2013. Incidence of dentinal defects after root canal preparation: Reciprocating versus rotary instrumentation. J. Endod. 39(4): 501-504.

Carlesi, T., G. Nigro, L. D. Giacomo, G. Plotino and V. A. Malagnino. 2018. Dentinal microcrack formation during root canal treatment with Mtwo instruments and microseal filling technique. J. Adv. Oral Res. 9(1-2): 31-37.

Cassimiro, M., K. Romeiro, L. Gominho, A. de Almeida, L. Costa and D. Albuquerque. 2017. Occurence of dentinal defects after root canal preparation with R-phase, M-wire and gold wire instruments: A micro-CT analysis. BMC Oral Health. 17(1): 93.

Dixit, H., M. Nair, N. Shah and V. Pandit. 2016. Incidence of dentinal crack formation during various endodontic procedures. Int. J. Oral Health Med. Res. 2(6): 125-128.

Gavini, G., M. dos Santos, C. L. Caldeira, M. E. L. Machado, L. G. Freire, E. F. Iglecias, O. A. Peters and G. T. M. Candeiro. 2018. Nickel-titanium instruments in endodontics: A concise review of the state of the art. Braz. Oral Res. 32: e67.

Hulsmann, M., O. A. Peters and P. M. H. Dummer. 2005. Mechanical preparation of root canals: Shaping goals, techniques and means. Endod. Top. 10(1): 30-76.

Jamleh, A., C. G. Adorno, A. Ebihara and H. Suda. 2016. Effect of nickel titanium file design on the root surface strain and apical microcracks. Aust. Endod. J. 42(1): 25-31.

Jamleh, A., T. Komabayashi, A. Ebihara, M. Nassar, S. Watanabe, T. Yoshioka, K. Miyara and H. Suda. 2015. Root surface strainduring canal shaping and its influence on apical microcrack development: A preliminary investigation. Int. Endod. J. 48(12): 1103-1111.

Khawaja, N., R. Lal, M. Rehman and S. K. Punjabi. 2016. Endodontics procedural errors. Prof. Med. J. 23(12): 1537-1540.

Liu, W. and B. Wu. 2016. Root canal surface strain and canal center transportation induced by 3 different nickel-titanium rotary instrument systems. J. Endod. 42(2): 299-303.

Machado, M. E. L., L. A. B. Sapia, S. Cai, G. H. R. Martins and C. K. Nabeshima. 2010. Comparison of two rotary systems in root canal preparation regarding disinfection. J. Endod. 36(7): 1238-1240.

Miguéns-Vila, R., B. Martín-Biedma, P. Varela-Patiño, M. Ruíz-Piñón and P. Castelo-Baz. 2017. Vertical root fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination. J. Clin. Exp. Dent. 9(10): e1218.

Modh, H., V. Sequeira, A. Belur, N. Arun, S. Dhas and G. Fernandes. 2018. Newer trends in endodontic treatment: A review. J. Dent. Med. Sci. 17(1): 14-16.

Patil, T. N., P. A. Saraf, R. Penukonda, S. S. Vanaki and L. Kamatagi. 2017. A survey on nickel titanium rotary instruments and their usage techniques by endodontists in India. J. Clin. Diagn. Res. 11(5): ZC29.

Ruddle, C. J. 2016. Single-file shaping technique: achieving a gold medal result. Dent Today. 35: 1-7.

Ruddle, C., P. Machtou and J. D. West. 2013. The shaping movement 5th generation technology. Dent Today. 32(4): 94.

Published

2020-12-30

How to Cite

Hama faraj, B. O., & Salman, R. F. (2020). Root Dentine Strain Generation during Root Canal Instrumentation with Rotation and Reciprocation Motions. Polytechnic Journal, 10(2), 66-70. https://doi.org/10.25156/ptj.v10n2y2020.pp66-70

Issue

Section

Research Articles